  1. Laminar Air Flow Bench For Tissue Culture Lab

    Technical Specification :Air cleanliness : ISO class 5 / class 100 / M 3.5 AREA Air velocities : 0.45 ± 0.05 mps (90±20 FPM)Air flow : horizontal / vertical Noise level : less than 67 db Vibration level : minimum Power supply : 230V AC ,1-, 50Hz MOC : GI powder coated / SS 304 /SS-316 side panel with glass /polycarbonate / acrylic two stage filtration EU5 intermediate filter (95% down to 5 micron )EU14 Hepa filter supply exhaust (99.999% down to 0.3 micron)Statically & dynamically balanced motor blower with isolate to reduce noise level Fluorescent lights with milky white diffuser Differential pressure gauge: 01 no. (hepa filter ) on/off switches (BL/FL/UV)Auxiliary powder socket : 5/15 amp for external equipment DOP port DQ,IQ,OQ,PQ Documentation Optional and accessories :A wide range of configurations to suit any containment application Front door (counter weighted / hinged) hour meter for UV air / gas cock Velocity display with high / low alarms filter chocking alarms Velocity display with High / Low Alarms Filter chocking alarms
    Send Inquiry
  2. Laminar Flow Workstation

    TECHNICAL SPECIFICATION Cleanliness : Class 100 Particle retention : 0.3 micron Velocity : 90FPM + 20%Illumination : 750 - 800 lumen Noise level : 60-65 decibels Power supply : 220v single phase ADVANTAGE Air-Stream is not directed at the operator causing less stress over Larger pieces of equipment cause less Larger working area Microbiological manipulations Bio-assays and sterility testing Bio clean protection for semi-automatic vial filling and bunging Operations in parenteral production, hospitals, pathological laboratories, microelectronics, optics, food and beverage, agriculture, animal husbandry, avionics and biotechnology Dry processing of electrons, electronic integration and micro feature assembly or, for automatic filling lines in parenteral production Microbiological labs or other research control centers engaged in investigative work with sub-toxic materials Providing protection for open vessels of chemicals, solvents or powders
    Send Inquiry
  3. Battery Operated Mobile Laminar Air Flow( Class-100)

    Technical specification Air cleanliness : ISO class 5 / class 100 / M .5 Area air velocities : 0.45±0.05 mps (90±20FPM)Air flow : Horizontal/Vertical Noise level : less than 65db Vibration level : minimum POWER SUPPLY : 230V AC, 1, 50HZ MOC: GI Powder Coated/ SS-304/ SS-316/Combination Inside: Side panel with all three side with coving EU7-Intermediate filter (95% down to 0.3 micron)EU14- HEPA filter- Supply/ Exhaust (99.999% down to 0.3 micron)Statically & dynamically balanced motor- blower with isolator to reduce noise level Fluorescent lights (Vpore proof)Differential pressure gauge : 01 No.( Hepa filter )ON/OFF switches on front facia (BL / FL/UV)Auxilliary power socket: 5/15 AMP For external equipment Dop Port DQ,IQ,OQ,PQ Documentation Battery back-up with Inverter (for 30mic. To Three hour)SS castor wheel with PU coated ( with locking arrangement )Options And Accessories Once through/ Re-circulating operation Side wall with SS/ Flexible PVC Strip/ Poly carbonate/ Acrylic sheet Front Flexible Strip PVC Curtain Velocity display with High/ Low Alarms
    Send Inquiry
  4. Laminar Air Flow Unit

    Laminar Airflow Bench offered by us is extensively used in several industries including medicine, healthcare, pharmaceutical, electronic devices manufacturing, etc. This bench us carefully designed to prevent the contamination of the biological and semiconductor samples. It is equipped with a HEPA filter that provides clean and uncontaminated air in a smooth and laminar flow towards the users. Apart from this, our offered Horizontal Laminar Airflow Bench can be availed from us at the market leading price range.
    Send Inquiry
  5. Laminar Air Flow Mobile Tent

    Laminar Flow Mobile Type Air Tent allows operation in sterile and particle free conditions because of the continuous flushing of the working area by a unidirectional and vertical and ultra-filtered airflow, it assures a full product protection..Design:Basic cabinet made from 1.2 mm thick GI with powder coated finish constructions with matt finish. Unit consists of HEPA filter plenum, each consists of a 0.3 micron HEPA filter, 10 micron Pre filters and Supply Air Blower etc., and suitable illumination and control switches etc will be provided.Function:The system works based on two-stage air filtration. The fresh air from the local atmosphere is sucked by the blower through pre-filters and passed into the working area through HEPA filters. Particles retained at pre filters level will be 10 micron and at HEPA Filter level will be 0.3 micron. Contaminated air from process area may be directly left into the local atmosphere or may be exhausted; this depends up on the nature contamination created during the process activity. Suitable for maintaining a positive pressure inside; on lockable wheels; easily dissembled and reassembled type; all filters installed on top or side.
    Send Inquiry
  6. Vertical / Horizontal Laminar Air Flow Unit

    Laminar Airflow Unit offered by us is extensively used in several industries including medicine, healthcare, pharmaceutical, electronic devices manufacturing, etc. This bench us carefully designed to prevent the contamination of the biological and semiconductor samples. It is equipped with a HEPA filter that provides clean and uncontaminated air in a smooth and laminar flow towards the users. Apart from this, our offered Horizontal Laminar Airflow Bench can be availed from us at the market leading price range.